Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.
Advertisement
Nature Communications volume 14, Article number: 5604 (2023)
2 Altmetric
Metrics details
The monitoring and control of DC-DC converters have become key issues since DC-DC converters are gradually playing increasingly crucial roles in power electronics applications such as electric vehicles and renewable energy systems. As an emerging and transforming technology, the digital twin, which is a dynamic virtual replica of a physical system, can potentially provide solutions for the monitoring and control of DC-DC converters. This work discusses the design and implementation of the digital twin DC-DC converter in detail. The key features of the physical and twin systems are outlined, and the control architecture is provided. To verify the effectiveness of the proposed digital twin method, four possible cases that may occur during the practical control scenarios of DC-DC converter applications are discussed. Simulations and experimental verification are conducted, showing that the digital twin can dynamically track the physical DC-DC converter, detect the failure of the physical controller and replace it in real time.
With the rapid advances in power electronics, DC-DC converters have become a crucial part of electric vehicles, DC microgrids, and renewable energy generation systems, which have been widely used in these areas and applications1. As illustrated in Fig. 1, the DC-DC converter plays a vital role in renewable energy systems, which can provide feasible voltage through the stepping up/down method for various loads with different voltage specifications. Considering the crucial role of DC-DC converters in power electronics applications, the control and monitoring of the status of DC-DC converters is of great importance2, and is also challenging due to intrinsic nonlinear characteristics3, therefore, the system state should be estimated online4. Various research studies have been conducted to address the nonlinear issues of nonlinear circuits, for example, fuzzy observer-based state estimation based on a slack variables technique5 and a switching multi-instant fuzzy observer to obtain less conservative results6. A recent study enlarged the application scope of fuzzy state estimation in nonlinear circuits with better estimation performance4.
Schematic of renewable energy systems, in which the DC-DC converter plays a vital role.
The digital twin (DT) is an important technology that can be employed in different industrial applications. Currently, the DT has become an increasingly popular research topic, with related research mainly focusing on smart manufacturing and Industry 4.07,8,9, web-based thermal power plants10, and driver assistance systems11,12. Digitized laboratories13, which are a kind of DT for laboratory setups, have also become a kind of DT online laboratory in recent years14,15.
As a transforming technology, the DT is one of the most studied topics within the power electronics area16,17, and is mainly focused on condition and health monitoring. In Ref. 16, a survey was carried out to identify the concepts, applications, challenges, and trends of DTs used in energy conversion systems based on power electronics. In Ref. 17, a DT-based health indicator estimation method for the condition monitoring of DC-DC converters was proposed, which is mainly used for monitoring the degradation level of the capacitor and MOSFET (metal-oxide-semiconductor field-effect transistor), the control perspective of which has not been considered. The application of DTs in DC-DC converters can potentially provide benefits such as health monitoring, fault diagnosing18 in photovoltaic systems and detection of system abnormalities for buck converters19.
In this work, a DT-based buck converter system is explored for simplicity without loss of generality, mainly from control perspectives. The proposed DT system includes both the hardware of the buck converter system (physical part) and the DT system (digital part) running in RT-LAB instead of a hardware-in-the-loop (HIL) approach that merely emulates the converter systems in RT-LAB20. The proposed DT system is proven to be effective for four possible cases that may occur during practical control scenarios: 1) tracking the physical system and ensuring dynamic characteristics when the reference value changes; 2) automatically adapting to the system model variation to achieve good control performance when the input voltage varies; 3) replacing the failed controller in the physical converter system with a DT controller; and 4) suiting physical DC-DC converters with different components, such as insulated gate bipolar transistors (IGBTs) and silicon carbide (SiC) MOSFETs.
To demonstrate the effectiveness of the DC-DC converter DT modeling method, four simulation cases are conducted as discussed in the following subsections. The parameters for the simulation are listed in Table 1, in which 48 V is a type of low-voltage dc microgrids that has been widely used for residential and communication applications21,22 and for simulation and experimental verification in microgrids and renewable energy studies23,24. The time step employed for running the DT is 0.1 ms.
In industry, especially in energy-related applications, voltage reference changes are commonly employed to evaluate the tracking capability of a proposed system25,26. Moreover, in the context of control-oriented research studies, it is prevalent to perform voltage reference changes, typically in the form of step-up or step-down adjustments, to assess the tracking performance27,28. Therefore, reference tracking, as a basic control task, is first verified in this case.
Although 48 V is considered in this work, different output voltages may be needed in other scenarios. For example, 20 V was used for charging batteries29. Fig. 2a shows the simulation results when the reference voltage is tuned from 0 V to 48 V and then from 48 V to 20 V. It can be seen that the DT system can track the physical buck converter system, while the mechanism model-based system cannot track the transient state.
a The output voltage when the reference voltage is changed from 0 V to 48 V and from 48 V to 20 V. b The output voltage when the input voltage is changed from 100 V to 90 V, and then from 90 V to 80 V. c The output voltage when controller failure is detected and replaced by the DT controller to ensure a functioning system. d SiC MOSFET is used as the switch in the circuit as the case in (c). Source data are provided as a Source Data file.
For a renewable system, due to the intermittent feature, the input voltage may vary from time to time. This case emulates a scenario in which the input voltage of a renewable system varies. From the subsequent modeling process, it can be concluded that once the input voltage changes, the control matrix (left[begin{array}{l}frac{{V}_{in}}{L}\ 0end{array}right]) will change, thus, the traditional mechanism model that is built based on a fixed input voltage Vin is no longer accurate.
Figure 2b shows the simulation results of the output voltage when the input voltage is changed from 100 V to 90 V, and then from 90 V to 80 V, in which the DT system can track the physical system better than the mechanism model-based system.
For practical applications, controller failure that is frequently encountered due to various reasons can cause system malfunctioning30, and may cause failures and damage to the entire system, which should be seriously considered and addressed to ensure reliable control. For power electronics applications, controller failure poses a significant challenge. For a photovoltaic power plant, down (not functional) probability is predominantly caused by controller and inverter failures31. Power converter and control circuit defects, such as sensor failure and controller failure, contribute to around 90% of electric drive failures32,33.
Figure 2c shows the simulation results of the output voltage when controller failure is detected and replaced by the DT controller. It can be concluded that the DT controller can ensure a functioning system when the physical controller fails.
SiC MOSFETs have a lower internal resistance and higher switching frequency than IGBTs, thus, they have been gradually applied in DC-DC converters34,35. To illustrate the generalization ability of the proposed method with different devices and a wide range of switching frequencies, in this case, the IGBT in the previous three cases has been replaced by an SiC MOSFET based on Ref. 36. The simulation result in Fig. 2d shows that it can achieve good control performance and adapt quickly in the case of controller failure and replacement.
Experimental verification is conducted with respect to the four cases presented in previous simulation subsections to verify the effectiveness of the proposed DT system. Fig. 3 shows the experimental setup for the verification, in which the upper part is the RT-LAB OP 5700, including the front and back views. The parameters for the DT experiments are the same as the simulation, as listed in Table 1. The time step used for running the DT is 0.1 ms, which is aligned with the simulation time step. The physical system is a buck converter that is controlled by a digital signal processor (DSP) TMS320F28335, while the dynamic model executed in RT-LAB works as the DT. Other hardware includes the power source IT-M3123, the IGBT intelligent power module PM50RLA120 (for experimental verification of Cases I to III), and the SiC MOSFET NTH4L040N120SC1 (for experimental verification of Case IV). The mechanism model is also run in RT-LAB to provide a reference for comparison with the DT model. As the changes cannot be seen from the outside, the three-dimensional model is not necessarily required for DT implementation.
The IGBT and SiC MOSFET used are also included.
This experimental verification corresponds to Simulation Case I for reference tracking. Figure 4 illustrates the experimental results when the reference voltage is changed from 0 V to 48 V and then from 48 V to 20 V. The DT system can track the physical buck converter system much better than the mechanism model-based system. Specifically, the twin system is observed to track changes more effectively in cases of abrupt reference variations, whereas the model-based system shows more oscillations during dynamic processes due to parasitic components in the circuit that were not considered during the modeling process. In contrast, the DT technique is capable of mitigating the adverse effects of these parasitic components. In some special scenarios, the dynamic characteristics are also worth considering1, which is also the advantage of the DT model compared to the mechanism model.
Experimental results of the output voltage when the reference voltage is changed from 0 V to 48 V and from 48 V to 20 V.
The purpose of this experiment is to verify the ability of the DT model to adapt to variations in the system model, which corresponds to Simulation Case II. For the experiment in Fig. 5, the mechanism model has no knowledge of the variance of the input voltage; therefore, its control output remains the same (see the duty cycle in the upper part of Fig. 5), which will affect the output voltage; thus, the mechanism model is not applicable. Observations of the converter’s duty cycle reveal that while the duty cycle of the twin system varies with changes in input voltage, the mechanism model remains unchanged and introduces errors even in steady-state conditions. However, the DT model can automatically adapt to the system model variation and adjust the control output μ to track the physical system (see the output voltage in the lower part of Fig. 5), and finally achieve good control performance, as shown in Fig. 5. This capability of the twin model to closely track variations in the system model proves advantageous for monitoring purposes and facilitates controller replacement.
Duty cycle source data are provided as a Source Data file.
As shown in Fig. 6, once the control input μ = 0 has been detected, which means that the physical controller of the physical buck converter system fails, the DT controller that is constructed based on hybrid twin modeling and runs in the RT-LAB will be activated in a very short time and works as the controller to ensure a functioning system. The DT controller can be regarded as a redundant system to improve the reliability and stability of the physical system. As a cost-effective option, once controller failure has been detected and the RT-LAB that works as a DT controller is activated, a new DSP controller can be used to replace the failed controller at appropriate timing.
Duty cycle source data are provided as a Source Data file.
Although direct comparison between methods can be challenging, the proposed method was compared to previous methods from three aspects: whether a physical DC-DC converter is involved, generalization ability, and applicable cases (three cases discussed in the previous sections). Table 2 shows the comparison results. The proposed method can be used for more scenarios for the monitoring and control of physical DC-DC converters compared with HIL20, DT-based monitoring37 and Internet-of-Thing based monitoring and control38.
To further verify the generalization ability of the proposed system and validate the results obtained from the simulation case in Simulation Case IV, experimental verification regarding the SiC MOSFET is also conducted with a new set of buck converter. Owing to the adoption of the SiC MOSFET, the new converter has a compact size compared to the IGBT-based counterpart, maintaining identical voltage and power levels.
The experimental results of the output voltage are shown in Fig. 7. In this case, the duty cycle is the same as that in Experimental Case III. The transient state is observed as shown at the top of Fig. 7, which demonstrates a remarkable dynamic tracking performance. For controller failure, the results show that the system can quickly adapt to the DT controller, thus, ensuring a smooth transition and maintaining good control performance. It can be seen that the error of the output voltage between the physical system and the DT system is 1.0 V, which is lower than 1.6 V in Fig. 6.
Experimental results of the output voltage when physical DSP controller failure is detected and has been replaced by the DT controller to ensure a functioning system (using SiC MOSFET as the switch).
In summary, in this work, methodologies to achieve DT based monitoring and control of DC-DC converters have been explored. A DT DC-DC converter has been designed and implemented that employs a hybrid twin modeling method. In total, four cases were investigated. Three cases with reference value tuning, system model variation, and controller failure that may occur during practical control scenarios were considered and demonstrated with simulation and experimental verification. The experimental results are in high agreement with the simulation results and are consistent with the theoretical analysis, which further validates the effectiveness of the proposed method. Simulation and experimental verification cases with an SiC MOSFET are also conducted and verify the generalization ability of the proposed method. The results show that dynamic system synchronization is achieved where the DT can dynamically track the physical system even when the system model varies, and controller failure can be detected and replaced, which verifies the effectiveness of the proposed DT method for monitoring and control. In future work, the DT could be used to address possible sensor failure, system condition diagnosis and prognosis, and optimal control. DT controller optimization is also a challenging and promising direction for future work.
In this section, the design and implementation of the DT DC-DC converter based on the physical DC-DC converter are introduced.
A typical DC-DC buck circuit is illustrated in Fig. 8a, along with its equivalent circuit during the ON and OFF states. Within one switching cycle of the switch, the system dynamic equations can be derived based on Kirchhoff’s laws39. During the ON state of the switch, the inductor current iL and the capacitor voltage uC can be expressed as follows:
where Vin represents the dc source input (not a constant for renewable energy systems due to the intermittent feature), and L, C, and R represent the inductance of the inductor, the capacitance of the capacitor, and the load resistance, respectively. During the OFF state of the switch, their state equations are given by
a Circuit diagram of the buck converter and the corresponding ON/OFF state. b Physical and twining DC-DC converter system. c Control architecture of the physical-DT DC-DC converter.
Let the duty cycle be defined as μ (0, 1), which is also the control input. Using the state-space averaging method, the unified state equation expression for the buck circuit over the entire switching cycle is obtained as
Figure 8b demonstrates the physical DC-DC converter and its DT counterpart. As a DT DC-DC converter, the two key features of the physical and twin systems are as follows.
1) Data transmission and dynamic DT: The physical system runs in real-time, while the DT can dynamically track the physical system. In this scenario, the physical system sends the data including iL, uC, and μ to its digital counterpart, based on which the DT updates its model and parameters. This also suits for variations of the system model. For a mechanism model that is built based on a fixed system offline, the model can be inaccurate once the system parameters change. While for a DT model in this work, it is updated online according to the real-time data from the physical system. Synchronization between the DT and the physical system can be ensured even if the physical model changes or parameters drift due to aging. 2) Information exchange and update: Since the DT monitors the physical system, once the controller failure of the physical system has been detected, the DT controller can be switched to control the physical system to ensure a functioning system.
Based on circuit theory, the process knowledge/mechanism modeling can be used. This model is easy to acquire and comprehend with actual measured values. However, it is generally fixed and thus suffers from parameter drift issues, which means that once the system model of the circuit system changes, the model has to be reconstructed from scratch. For example, Vin is typically fixed when using mechanism-based modeling owing to cost considerations. In addition, in renewable energy systems, voltage fluctuations (changes of Vin) are common due to variability on the generation side. Even if Vin is not fixed and measurable, the R, L and C components within a specific DC-DC system may be time-varying, which makes mechanism-based modeling challenging. To solve this issue, a mechanism-data hybrid modeling method is adopted for the design and implementation of the DT model.
To realize the hybrid twin modeling, system (3) is discretized to the form of (4), where y and (hat{y}) are the observed output and estimated value, respectively. θ and (hat{theta }) are the parameter matrix and estimated parameter matrix, respectively. ψ is the input vector. Ad and Bd (noting that Vin is included in Bd) are the system and control matrices discretized from (3). It is crucial to emphasize that (4) represents a time-variant system, capable of accurately reflecting the parameters of the physical system. This indicates that the proposed system remains applicable and effective, even in the presence of parameter drift, such as degradation in capacitors or MOSFETs.
Different approaches can be employed for state estimation, for example, Kalman filters and observers, however, it has been proven that the Kalman filter provides better estimation performance for states and exhibits satisfactory estimation accuracy in the presence of noise40. The DT is connected with the physical system, which contains considerable noise, therefore, traditional parameter estimation methods are not effective. The Kalman filter adaptation algorithm41, which possesses several advantages, such as the ability to reduce noise, low computational complexity, good convergence42, and high time efficiency, can be used to address this issue:
Estimation (5) can be employed to update θ in real time, where the gain K can be designed by a Kalman-filter-based recursive estimation algorithm and calculated using (6). As Vin is included in Bd (thus in θ), it is also updated in real time. Q(t) can be derived from (7) and (8), where R1 is the covariance matrix of the Gaussian white noise of true parameters and R2 is the variance of the noise source. The computational cost of the Kalman-filter-based estimation is closely linked to the number of estimated state variables43. For the case of the model with two estimated variables in this work, the computational cost is relatively low. For complex nonlinear models and systems with more state variables, the feedback linearization technique can be an effective solution for reducing complexity1.
It should be noted that the Kalman filter is only applied to the DT model, while the parameters in the mechanism-based model are actual measured values. The aim of the mechanism-based model is to accurately represent the fundamental physical principles and dynamics of the DC-DC converter. The DT model, on the other hand, facilitates real-time analysis, monitoring, and control through live data, making the Kalman filter an advantageous choice due to its capacity to enhance state estimation accuracy and enable effective control.
Fig. 8c illustrates the control architecture of the physical-DT DC-DC converter, which includes two closed loops, one for the physical system and another for the DT system. The control architecture is based on the two aforementioned key features of the physical and twin systems, namely, the DT model and its parameters are updated in real-time based on the physical system, and the DT controller can be used to control the physical system if physical controller failure occurs.
Source data are provided with this paper.
Dai, X., Liu, G.-P., Deng, Q. & Zeng, W. Global optimal cooperative control of multiple dc-dc converter systems for dynamic consensus. IEEE Trans. Power Electron. 36, 14340–14352 (2021).
Article  ADS  Google Scholar 
RakhtAla, S. M., Yasoubi, M. & HosseinNia, H. Design of second order sliding mode and sliding mode algorithms: a practical insight to dc-dc buck converter. IEEE/CAA J. Autom. Sinica 4, 483–497 (2017).
Article  MathSciNet  Google Scholar 
Zhang, J., Li, S., Ahn, C. K. & Xiang, Z. Sampled-data output voltage regulation for a dc–dc buck converter nonlinear system with actuator and sensor failures. Nonlinear Dyn. 99, 1243–1252 (2020).
Article  MATH  Google Scholar 
Xie, X., Qiu, X. & Xia, J. Enhanced fuzzy state estimation of discrete-time nonlinear circuits via two relaxed measures. IEEE Trans. Circuits Syst. II 70, 211–215 (2023).
Google Scholar 
Xie, X., Qiu, X. & Gu, Z. Observer-based multi-instant fuzzy state estimation of discrete-time nonlinear circuits via a new slack variables technique. IEEE Trans. Circuits Syst. II 69, 2191–2195 (2022).
Google Scholar 
Xie, X., Xu, C. & Gu, Z. Further studies on state estimation of discrete-time nonlinear circuits based on a switching-type multi-instant fuzzy observer. IEEE Trans. Circuits Syst. II 69, 3505–3509 (2022).
Google Scholar 
Schluse, M., Priggemeyer, M., Atorf, L. & Rossmann, J. Experimentable digital twins–streamlining simulation-based systems engineering for industry 4.0. IEEE Trans. Ind. Informat. 14, 1722–1731 (2018).
Article  Google Scholar 
Tao, F., Zhang, H., Liu, A. & Nee, A. Y. Digital twin in industry: State-of-the-art. IEEE Trans. Ind. Informat. 15, 2405–2415 (2019).
Article  Google Scholar 
Wang, Q., Jiao, W., Wang, P. & Zhang, Y. Digital twin for human-robot interactive welding and welder behavior analysis. IEEE/CAA J. Autom. Sinica 8, 334–343 (2021).
Article  Google Scholar 
Lei, Z. et al. Toward a web-based digital twin thermal power plant. IEEE Trans. Ind. Informat. 18, 1716–1725 (2022).
Article  Google Scholar 
Alam, K. M. & El Saddik, A. C2PS: A digital twin architecture reference model for the cloud-based cyber-physical systems. IEEE Access 5, 2050–2062 (2017).
Article  Google Scholar 
Schluse, M., Atorf, L. & Rossmann, J. Experimentable digital twins for model-based systems engineering and simulation-based development. In Proc. IEEE Annu. Int. Syst. Conf. 1–8 (2017).
de la Torre, L. et al. Automatic generation and easy deployment of digitized laboratories. IEEE Trans. Ind. Informat. 16, 7328–7337 (2020).
Article  Google Scholar 
Lei, Z., Zhou, H., Hu, W. & Liu, G.-P. Flipping laboratories toward future experimentation systems: The blended use of hands-on, pocket, and online laboratories. IEEE Ind. Electron. Mag. 17, 48–60 (2023).
Article  Google Scholar 
Lei, Z., Zhou, H., Hu, W. & Liu, G.-P. Web-based digital twin online laboratories: Methodologies and implementation. Digital Twin 2, 1–15 (2022).
Article  Google Scholar 
Chen, H., Zhang, Z., Karamanakos, P. & Rodriguez, J. Digital twin techniques for power electronics-based energy conversion systems: A survey of concepts, application scenarios, future challenges, and trends. IEEE Ind. Electron. Mag. 17, 20–36 (2023).
Article  Google Scholar 
Peng, Y., Zhao, S. & Wang, H. A digital twin based estimation method for health indicators of dc–dc converters. IEEE Trans. Power Electron. 36, 2105–2118 (2021).
Article  ADS  Google Scholar 
Jain, P. et al. A digital twin approach for fault diagnosis in distributed photovoltaic systems. IEEE Trans. Power Electron. 35, 940–956 (2019).
Article  ADS  Google Scholar 
Milton, M., De La O, C., Ginn, H. L. & Benigni, A. Controller-embeddable probabilistic real-time digital twins for power electronic converter diagnostics. IEEE Trans. Power Electron. 35, 9850–9864 (2020).
Article  ADS  Google Scholar 
Xing, L. et al. Voltage restoration and adjustable current sharing for dc microgrid with time delay via distributed secondary control. IEEE Trans. Sustain. Energy 12, 1068–1077 (2021).
Article  ADS  Google Scholar 
Sahoo, H., Kapat, S. & Singh, B. Small-signal modelling and analysis of converter interactivity in 48 v dc grid. IEEE Trans. Ind. Appl. (to be published, https://doi.org/10.1109/TIA.2023.3275884).
Sabry, A. H., Shallal, A. H., Hameed, H. S. & Ker, P. J. Compatibility of household appliances with dc microgrid for pv systems. Heliyon 6 (2020).
Castillo-Calzadilla, T. et al. Is it feasible a massive deployment of low voltage direct current microgrids renewable-based? a technical and social sight. Renew. Sustain. Energy Rev. 161, 112198 (2022).
Article  Google Scholar 
Gerber, D. L., Nordman, B., Brown, R. & Poon, J. Cost analysis of distributed storage in ac and dc microgrids. Appl. Energy 344, 121218 (2023).
Article  Google Scholar 
Sadabadi, M. S., Mijatovic, N., Trégouët, J.-F. & Dragičević, T. Distributed control of parallel dc–dc converters under fdi attacks on actuators. IEEE Trans. Ind. Electron. 69, 10478–10488 (2022).
Article  Google Scholar 
Zhuo, S. et al. Enhanced robust control of a dc–dc converter for fuel cell application based on high-order extended state observer. IEEE Trans. Transport. Electrific. 6, 278–287 (2020).
Article  Google Scholar 
Liu, G.-P. Tracking control of multi-agent systems using a networked predictive PID tracking scheme. IEEE/CAA J. Autom. Sin. 10, 216–225 (2023).
Article  Google Scholar 
Liu, G.-P. Coordinated control of networked multiagent systems via distributed cloud computing using multistep state predictors. IEEE Trans. Cybern. 52, 810–820 (2022).
Article  PubMed  Google Scholar 
Chuang, Y.-C. High-efficiency zcs buck converter for rechargeable batteries. IEEE Trans. Ind. Electron. 57, 2463–2472 (2010).
Article  Google Scholar 
Sun, X.-M., Liu, G.-P., Rees, D. & Wang, W. Stability of systems with controller failure and time-varying delay. IEEE Trans. Autom. Control 53, 2391–2396 (2008).
Article  MathSciNet  MATH  Google Scholar 
Shahidirad, N., Niroomand, M. & Hooshmand, R.-A. Investigation of PV power plant structures based on Monte Carlo reliability and economic analysis. IEEE J. Photovolt. 8, 825–833 (2018).
Google Scholar 
Song, Y. & Wang, B. Survey on reliability of power electronic systems. IEEE Trans. Power Electron. 28, 591–604 (2013).
Article  ADS  Google Scholar 
Joseph, A., Desingu, K., Semwal, R., Chelliah, T. R. & Khare, D. Dynamic performance of pumping mode of 250 MW variable speed hydro-generating unit subjected to power and control circuit faults. IEEE Trans. Energy Convers. 33, 430–441 (2018).
Article  ADS  Google Scholar 
Kumaravel, S. et al. Ultra-voltage gain bidirectional dc–dc converter with reduced switch voltage stress and improved efficiency. IEEE Trans. Circuits Syst. II 69, 4468–4472 (2022).
Google Scholar 
Zhang, L. et al. Performance evaluation of high-power SiC MOSFET modules in comparison to Si IGBT modules. IEEE Trans. Power Electron. 34, 1181–1196 (2019).
Article  ADS  Google Scholar 
Jin, M., Gao, Q., Wang, Y. & Xu, D. A temperature-dependent SiC MOSFET modeling method based on MATLAB/Simulink. IEEE Access 6, 4497–4505 (2018).
Article  Google Scholar 
Di Nezio, G., Di Benedetto, M., Lidozzi, A. & Solero, L. Digital twin based real-time analysis of dc-dc boost converters. In Proc. IEEE Energy Convers. Congr. Expo. 1–7 (2022).
Sivasankar, N. & Devabalaji, K. Smart multiport bidirectional non-isolated dc-dc converter for solar pv-battery systems. In Int. Conf. Electr., Electron., Inf. and Commun. Technol. 1–8 (2022).
Tan, R. H. & Hoo, L. Y. Dc-dc converter modeling and simulation using state space approach. In IEEE Conf. Energy Convers. 42–47 (IEEE, 2015).
Hui, J. & Yuan, J. Kalman filter, particle filter, and extended state observer for linear state estimation under perturbation (or noise) of MHTGR. Prog. Nucl. Energy. 148, 104231 (2022).
Article  CAS  Google Scholar 
Ljung, L. System Identification: Theory for the User (Prentice-Hall PTR, Upper Saddle River, NJ, 1999).
Li, M., Kang, R., Branson, D. T. & Dai, J. S. Model-free control for continuum robots based on an adaptive kalman filter. IEEE/ASME Trans. Mechatronics 23, 286–297 (2018).
Article  Google Scholar 
Raitoharju, M. & Piché, R. On computational complexity reduction methods for kalman filter extensions. IEEE Aerosp. Electron. Syst. Mag. 34, 2–19 (2019).
Article  Google Scholar 
Download references
This work was supported in part by the National Natural Science Foundation of China under Grant 62103308 (Z.L.), Grant 62073247 (W.H.), Grant 62173255 (G.L.), and Grant 62188101 (G.L.), in part by the Fundamental Research Funds for the Central Universities under Grant 2042023kf0095 (Z.L.), and in part by the China Postdoctoral Science Foundation under Grant 2022T150496 (Z.L.).
Department of Artificial Intelligence and Automation, School of Electrical Engineering and Automation, Wuhan University, Wuhan, 430072, China
Zhongcheng Lei, Hong Zhou, Xiaoran Dai & Wenshan Hu
Center for Control Science and Technology, Southern University of Science and Technology, Shenzhen, 518055, China
Guo-Ping Liu
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
Z.L. conceived the idea and wrote the manuscript. X.D. performed the simulation and experiments. Z.L. and X.D. analyzed data and interpreted the results. Funding was acquired by Z.L., W.H., and G.L. H.Z. was project administrator. All authors reviewed and edited the manuscript.
Correspondence to Xiaoran Dai or Wenshan Hu.
The authors declare no competing interests.
Nature Communications thanks the anonymous reviewer(s) for their contribution to the peer review of this work. A peer review file is available.
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
Lei, Z., Zhou, H., Dai, X. et al. Digital twin based monitoring and control for DC-DC converters. Nat Commun 14, 5604 (2023). https://doi.org/10.1038/s41467-023-41248-z
Download citation
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-023-41248-z
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.
Advertisement
Nature Communications (Nat Commun) ISSN 2041-1723 (online)
© 2023 Springer Nature Limited
Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

source

Leave a Reply

Your email address will not be published. Required fields are marked *